Name

Turbine Flow meter

Model

DM-11

TM-11

Explosion
proof
construction

Non-explosion-proof

Intrinsically safe construction(ia2BT4Gb)

Measurement
system

Magnetic type

Description

The turbine flow meter is designed to measure the flow rate of a high-temperature, high-pressure and/or combustible fluid passing through piping.

Operating
principles
A turbine installed in a pipe rotates faster in proportion to increasing flow rates of the fluid in the pipe. The flow rate of the fluid in the pipe is measured by detecting the speed of the turbine magnetically from outside the pipe.
Specifications
Measurement range Depends on the pipe diameter.
Output signal DC4~20mA DC1~5V ※One of the above signal
Input power AC105V/210V 50/60Hz or DC24V
Power consumption 20W
Allowable temperature Detector:   Model MS-11: -20℃~+80℃
Transducer: Model TR-31: -10℃~+50℃
        Model TR-32: -10℃~+50℃
Receiver: -10℃~+50℃
Special cable: Model MVVS 2C: -10℃~+60℃
Weight Transducer: Model TR-31: 2.0kg
        Model TR-32: 2.0kg
Receiver: 0.35kg
Size Transducer: Model TR-31: 154(W)×95(D)×166(H)
        Model TR-32: 154(W)×95(D)×166(H)
Receiver: 49(W)×122(D)×79(H) (mm)
Installation Detector: Bolts and nuts mounting, etc.
Material Detector: SUS304, etc.
Head case: SUS304, etc.
Configuration

Model TM-11
(Intrinsically safe construction / ia2BT4Gb)
<Totally separated transducer type>

Products and Service