If the substance to be measured is a powder (or in the form of flakes) and tends to form lumps, it might build up and solidify on the probe due to consolidation loads. This blower-equipped level switch blows out a small amount of air (nitrogen) through a port at the tip or side of the probe to keep the powder from solidifying while detecting the level of the powder.
Measurement system | Automatic correction capacitance system |
Stable detection range | Min. ≦ 0.1pF (Type Y) Max. ≧15000pF (Type C) Peculiar resistor∞~0.5Ω (Type Y~Type C |
Output contact | Model NQH-BL: a, c, b 200V 1A 100VA (Non-inductive load) / Open collector / Thyristor / SSR Model NSH-BL (Model PS-7): a, c, b 200V 1A 100VA (Non-inductive load) Model NSH-BL (Model PS-8): a, c, b 250V 5A (Non-inductive load) |
Input power | Model NQH-BL: AC105V/210V 50/60Hz or DC24V Model NSH-BL (Model PS-7): AC105V/210V 50/60Hz Model NSH-BL (Model PS-8): AC105V/210V 50/60Hz |
Power consumption | Model NQH-BL: 4.5W Model NSH-BL: 4W |
Time lag | Model NQH-BL : 0~10sec Variable (option) |
Allowable temperature | Detector: -200℃~+1100℃ (Depends on the specifications) Transducer: Model PS-3BL: -10℃~+50℃ Transducer: Model TR-6BL: -25℃~+70℃ Power source: Model PS-7: -10℃~+50℃ Power source: Model PS-8: -10℃~+50℃ Special cable: Model RG (Standard type): -10℃~+60℃ Special cable: Model TEF(Heat resistance use): -200℃~+260℃ |
Allowable load | Detector: -200℃~+1100℃ (Depends on the specifications) |
Allowable pressure | Detector: 100MPa (approx. 1020kg/cm2G) (Depends on the specifications) |
Weight | Transducer: Model PS-3BL: 2.0kg Transducer: Model TR-6BL: 1.75kg Power source: Model PS-7: 2.0kg Power source: Model PS-8: 7.8kg |
Size | Transducer: Model PS-3BL: 154(W)×95(D)×166(H) Transducer: Model TR-6BL: 154(W)×95(D)×166(H) Power source: Model PS-7: 80(W)×101(D)×210(H) Power source: Model PS-8: 220(W)×78(D)×262(H) (mm) |
Installation | Detector: Flange mounting Screws mounting Ferrule IDF, etc. |
Material | Detector: SUS304 SUS316 SUS316L Hastelloy Titanium Tantalum Nickel PTFE Ceramic, etc. Lining: PTFE Glass Rubber, etc. Head case: Light alloy SUS304 Salt resistant paint case, etc. |
Measurement system | Vibrating system (Magnet bias system) |
Output contact | Model DTA-BL: a, c, b 200V 1A 100VA (Non-inductive load) / Open collector / Thyristor / SSR Model STA-BL (Model PS-7): a, c, b 200V 1A 100VA (Non-inductive load) |
Input power | Model DTA-BL: AC105V/210V 50/60Hz or DC24V Model STA-BL (Model PS-7): AC105V/210V 50/60Hz |
Power consumption | Model DTA-BL: 5W Model STA-BL: 4W |
Vibration frequency | 100Hz~10KHz(Depends on the specifications) |
Allowable temperature | Detector: -200℃~+600℃ (Depends on the specifications) Transducer: Model PS-19BL: -10℃~+50℃ Transducer: Model TR-7BL: -25℃~+70℃ Power source: Model PS-7: -10℃~+50℃ Special cable: Model RG (standard type): -10℃~+60℃ Special cable: Model TEF (heat resistance use): -200℃~+260℃ |
Allowable load | Detector: 500㎏ Concentrated at detection tip (Depends on the specifications) |
Allowable pressure | Detector: 10MPa (approx. 102kg/cm2G) (Depends on the specifications) |
Weight | Transducer: Model PS-19BL: 2.0kg Transducer: Model TR-7BL: 1.75kg Power source: Model PS-7: 2.0kg |
Size | Transducer: Model PS-19BL: 154(W)×95(D)×166(H) Transducer: Model TR-7BL: 154(W)×95(D)×166(H) Power source: Model PS-7: 80(W)×101(D)×210(H) (mm) |
Installation | Detector: Flange mounting Screws mounting Ferrule IDF, etc. |
Material | Detector: SUS304 SUS316 SUS310 SUS321 SUS329 Hastelloy, etc. Lining: PTFE Rubber, etc. Head case: Light alloy SUS304 Salt resistant paint case, etc. |
This model is composed of detector unit, transducer (relay power source) and special cable. Transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This has the same characteristics as those of Integrated transducer unit type as to performance.
This model is composed of detector unit with self-contained transducer and relay power source (Model PS-7). The transducer contained in the detector head requires no special cable. For this reason, the dangerous area may be kept away unlimitedly from the safe area. As to performance, this model has the same characteristics as those of Model NQH-BL.
This model is composed of detector unit, transducer, relay power source (Model PS-7) and special cable. Transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This model has the same characteristics as those of Model NQH-BL and the equivalent performance to those of Integrated transducer unit type.
This model is composed of detector unit with self-contained transducer and relay power source (Model PS-8). The transducer contained in the detector head requires no special cable. For this reason, the dangerous area may be kept away unlimitedly from the safe area. As to performance, this model has the same characteristics as those of Model NQH-BL.
This model is composed of detector unit, transducer, relay power source (Model PS-8) and special cable. The transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This model has the same characteristics as those of Model NQH-BL and the equivalent performance to those of Integrated transducer unit type.
This model is composed of detector unit, transducer (relay power source) and special cable. Transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This has the same characteristics as those of Integrated transducer unit type as to performance.
This model is composed of detector unit with self-contained transducer and relay power source (Model PS-7). The transducer contained in the detector head requires no special cable. For this reason, the dangerous area may be kept away unlimitedly from the safe area. As to performance, this model has the same characteristics as those of Model DTA-BL.
This model is composed of detector unit, transducer, relay power source (Model PS-7) and special cable. Transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This model has the same characteristics as those of Model DTA-BL and the equivalent performance to those of Integrated transducer unit type.