Name

Foam detecting switch

Measurement system

Capacitance system

Impedance system

Model

NQH-FO
NSH-FO

NQS-FO
NSS-FO

Explosion
proof
construction

Non-explosion-proof
Intrinsically safe construction(i3nG5)
Flameproof
construction(d2G4

Non-explosion-proof
Intrinsically safe construction(i3nG5)

Object to be
measured

Soap foam, beer foam, latex foam, etc.

Beer foam Foam blowing
Description

This switch is designed to detect the soap foam, beer foam, latex foam, etc. Either capacitance system or impedance system can be offered depending on the characteristics of the objects to be measured.

Specifications

NQH-FO
(Non-explosion-proof type)
NSH-FO
(Explosion-proof type)

Measurement system Automatic correction capacitance system
Stable detection range Min. ≦ 0.1pF (Type Y)
Max. ≧ 15000pF (Type C)
Peculiar resistor ∞~5Ω (Type Y~Type C)
Output contact Model NQH-FO: a,c,b 200V 1A 100VA (Non-inductive load) /
         Open collector / Thyristor / SSR
Model NSH-FO (Model PS-7): a,c,b 200V 1A 100VA (Non-inductive load)
Model NSH-FO (Model PS-8): a,c,b 250V 5A (Non-inductive load)
Input power Model NQH-FO: AC105V/210V 50/60Hz or DC24V
Model NSH-FO (Model PS-7): AC105V/210V 50/60Hz
Model NSH-FO (Model PS-8): AC105V/210V 50/60Hz
Power consumption Model NQH-FO: 4.5W
Model NSH-FO: 4W
Time lag Model NQH-FO: 0~10sec Variable (option)
Allowable temperature Detector: -200℃~+1100℃ (Depends on the specifications)
Transducer:  Model PS-3FO: -10℃~+50℃
Transducer:  Model TR-6FO: -25℃~+70℃
Power source: Model PS-7:   -10℃~+50℃
Power source: Model PS-8:   -10℃~+50℃
Special cable:  Model RG (standard type):    -10℃~+60℃
Special cable:  Model TEF (heat resistance use):  -200℃~+260℃
Allowable load Detector: 2000㎏ Concentrated at detection tip
      (Depends on the specifications)
Allowable pressure Detector: 100MPa (approx. 1020kg/cm2G)
      (Depends on the specifications)
Weight Transducer:  Model PS-3FO: 2.0kg
Transducer:  Model TR-6FO: 1.75kg
Power source: Model PS-7:    2.0kg
Power source: Model PS-8:    7.8kg
Size Transducer:  Model PS-3FO: 154(W)×95(D)×166(H)
Transducer:  Model TR-6FO: 154(W)×95(D)×166(H)
Power source: Model PS-7:    80(W)×101(D)×210(H)
Power source: Model PS-8:    220(W)×78(D)×262(H) (mm)
Installation Detector: Flange mounting Screws mounting  Ferrule IDF, etc.
Material Detector: SUS304 SUS316 SUS316L Hastelloy Titanium
      Tantalum Nickel PTFE Ceramic, etc.
Lining: PTFE Glass Rubber, etc.
Head case: Light alloy SUS304 Salt resistant paint case, etc.
Specifications

NQS-FO
(Non-explosion-proof type)
NSS-FO
(Explosion-proof type)

Measurement system Impedance system
Stable detection range Min. ≦ 0.5pF
Max. ≧ 1000pF
Peculiar resistor ∞~0.5Ω
Output contact Model NQS-FO: a,c,b 250V 5A (Non-inductive load) /
         Open collector / Thyristor / SSR
Model NSS-FO (Model PS-7): a,c,b 200V 1A 100VA (Non-inductive load)
Input power Model NQS-FO: AC105V/210V 50/60Hz or DC24V
Model NSS-FO (Model PS-7): AC105V/210V 50/60Hz
Power consumption Model NQS-FO: 7W
Model NSS-FO: 4W
Allowable temperature Detector: -200℃~+1100℃ (Depends on the specifications)
Transducer:  Model PS-1FO: -10℃~+50℃
Transducer:  Model TR-1FO: -25℃~+70℃
Power source: Model PS-7:   -10℃~+50℃
Special cable:  Model DSC-15 (high accuracy use):   -10℃~+60℃
Special cable:  Model DSC-05 (small size):      -10℃~+60℃
Special cable:  Model DSC-13 (heat resistance use): -50℃~+200℃
Allowable load Detector: 2000㎏ Concentrated at detection tip
      (Depends on the specifications)
Allowable pressure Detector: 100MPa (approx. 1020kg/cm2G)
      (Depends on the specifications)
Weight Transducer:  Model PS-1FO: 4.3kg
Transducer:  Model TR-1FO: 4.3kg
Power source: Model PS-7:   2.0kg
Size Transducer:  Model PS-1FO: 200(W)×149(D)×220(H)
Transducer:  Model TR-1FO: 200(W)×149(D)×220(H)
Power source: Model PS-7:   80(W)×101(D)×210(H) (mm)
Installation Detector: Flange mounting Screws mounting  Ferrule IDF, etc.
Material Detector: SUS304 SUS316 SUS316L Hastelloy Titanium
      Tantalum Nickel PTFE Ceramic, etc.
Lining: PTFE Glass Rubber, etc.
Head case: Light alloy SUS304 Salt resistant paint case, etc.
Configuration
(Capacitance system)

Model NQH-FO-1
(Non-explosion-proof type)
<Integrated transducer unit type>

This model is of compact type in which both detector unit and transducer are integrated.

Configuration
(Capacitance system)

Model NQH-FO-2
(Non-explosion-proof type)
<Separated transducer type>

This model is composed of detector unit, transducer (relay power source) and special cable. Transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This is Non-explosion-proof type and has the same characteristics as those of Integrated transducer unit type as to performance.

Configuration
(Capacitance system)

Model NSH-FO-1-1
(Intrinsically safe construction / i3nG5)
<Integrated transducer unit type>

This model is composed of detector unit with self-contained transducer and relay power source (Model PS-7). The transducer contained in the detector head requires no special cable. For this reason, the dangerous area may be kept away unlimitedly from the safe area. As to performance, this model has the same characteristics as those of Model NQH-FO.

Configuration
(Capacitance system)

Model NSH-FO-2-1
(Intrinsically safe construction / i3nG5)
<Separated transducer type>

This model is composed of detector unit, transducer, relay power source (Model PS-7) and special cable. The transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This model has the same characteristics as those of Model NQH-FO and the equivalent performance to those of Integrated transducer unit type.

Configuration
(Capacitance system)

Model NSH-FO-1-2
(Flameproof construction / d2G4)
<Integrated transducer type>

This model is composed of detector unit with self-contained transducer and relay power source (Model PS-8). The transducer contained in the detector head requires no special cable. For this reason, the dangerous area may be kept away unlimitedly from the safe area. As to performance, this model has the same characteristics as those of Model NQH-FO.

Configuration
(Capacitance system)

Model NSH-FO-2-2
(Flameproof construction / d2G4)
<Separated transducer type>

This model is composed of detector unit, transducer, relay power source (Model PS-8) and special cable. The transducer may be installed far from the area exposed to Heat, Steam, Vibration, Powder or Gas. This model has the same characteristics as those of Model NQH-FO and the equivalent performance to those of Integrated transducer unit type.

Configuration
(Impedance system)

Model NQS-FO
(Non-explosion-proof type)
<Separated transducer type>

This model is composed of detector unit, transducer and special cable.

Configuration
(Capacitance system)

Model NSS-FO
(Intrinsically safe construction / i3nG5)
<Totally separated detector unit type>

This model is composed of detector unit, transducer, relay power source and special cable that is 3 core control cable. As the transducer is designed to be installed in a dangerous area, the special cable can be made short enough to minimize picked-up noises, thus permitting a stable performance to be obtainable. As to performance, this model has the same characteristics as those of Model NQS-FO.